PURPOSE: To show the phase shift between components in a series RLC circuit.
DESCRIPTION: An RLC circuit has been constructed with linear isolation transformers to eliminate grounding when the circuit is attached to a four-trace oscilloscope. Using this device, the signals across the input, R, L, and C can be viewed simultaneously as the oscillator frequency is swept through resonance.
Click here to see the complete circuit.
Click here for short descriptive paper in Microsoft Word format
REFERENCES: (PIRA 5L20.11)
EQUIPMENT: RLC circuit, oscillator, and four-trace oscilloscope.
SETUP TIME: 10 min.
![]() |
![]() |
![]() |
![]() |
![]() |